Models 424 and 424FS Installation 10
Lock Installation
IMPORTANT NOTE: I
f you are adding an accessory lock kit
to your wine storage unit, it should be installed before you
position the unit.
The accessory lock kit and additional instructions are
available through your authorized Sub-Zero dealer, or call
Sub-Zero at 800-222-7820. You can also visit our website
at subzero.com.
POSITION THE UNIT
IMPORTANT NOTE:
If for any reason the wine storage unit
has been laid on its back or side, you must allow the unit
to stand upright for a minimum of 24 hours before con-
necting power.
Plug the power cord into the 15 amp grounded electrical
outlet. With power applied to the appliance, check for
lighting and cooling before going any further. Once you are
satisfied that the unit is operating properly, shut off power
to the electrical outlet at the circuit breaker and proceed.
I
f a home alarm system is to be used with the wine
storage unit, the lead wires should be threaded into the
compressor compartment before you position the unit.
Refer to home alarm connections on page 11, for the
location of these lead wires. After the unit is in position,
the alarm wiring can be completed from the front.
Pre-level the wine storage unit before sliding it into
position. Leveling cannot be completed with the unit
pushed back in the installation opening.
For model 424FS, adust the leveling legs so the top of the
unit is no more than 34
5
/8" (879) above the floor. This is to
allow the unit to engage the anti-tip bracket properly.
Center the model 424FS in front of the anti-tip bracket.
Slide the unit into position, making sure the anti-tip
bracket is engaged properly.
IMPORTANT NOTE: When the wine storage unit is
installed, the anti-tip bracket will be positioned just below
the engaging bracket on the unit. It is not necessary to
raise the unit up so that it locks into the anti-tip bracket,
but the unit must be in alignment with the anti-tip bracket.
The wine storage unit provides the best access to its
contents when the front surface of the door panel extends
out from surrounding cabinets approximately
1
/4" (6). For
model 424FS, if there are no surrounding cabinet surfaces
to gauge depth, slide the unit back until it engages the
anti-tip bracket.
IMPORTANT NOTE: The floor under the wine storage unit
must be at the same level as the surrounding finished floor
to allow for removal of the unit for servicing.
Shut off the power to the electrical outlet.